ANALOG SURFACEMOUNT SENSOR HT MASS

Mechanical and Environmental Specifications

Parameter Minimum Maximum Units
Outside Diameter*
 
1.37
3.5
inches
cm
Length*

19
38.1
inches
cm
Operating Temperature
0
+32
200°
392°
°C
°F
Survival Temperature
-40
-40
210°
410°
°C
°F
Vibration, Random
(Limited by accelerometers)
 
20
g RMS, 15-500 Hz
Shock
(Limited by accelerometers)
 
1000
g, 0.5 mSec, half-sine

* Dimensions do not include running gear, centralizers or axial shock absorbers

Instrument Accuracy Specifications

Parameter Maximum Units
Inclination accuracy, absolute*
Inclination spread on axial rotation at 90º Inc
±0.10
<0.20
degrees
degrees
Azimuth accuracy, absolute, 90° Inc
±0.50
degrees
Azimuth spread axial rotation, 10° through 90°
<1.0
degrees
Tool Face accuracy, axial rotation at 90° Inc
±1.0
degrees
Total g field accuracy
±3.0
mG
Total H field accuracy, absolute
±3.0
nT

* Absolute accuracy is achieved when the instrument is tested in a controlled environment using calibrated and certified reference position

 

 
  ©2012. MicroTesla. All Rights Reserved.