MICROTESLA ANALOG SENSORS TECHNICAL SPECIFICATIONS

Mechanical and Environmental Specifications

Parameter Minimum Maximum Units
Outside Diameter*
 
1.375
3.5
inches
cm
Length*

27
68.6
inches
cm
Operating Temperature
0
+32
150, 175
302, 347
ºC
ºF
Survival Temperature
-40
-40
160, 185
320, 365
ºC
ºF
Vibration, Random (limited by accelerometers)
 
20
g RMS, 15-500 Hz
Shock (limited by accelerometers)
 
1000
g, 0.5 mSec, half-sine

*Dimensions do not include running gear, centralizers, or axial shock absorbers

Instrument Accuracy Specifications

Parameter Maximum Units
Inclination accuracy, absolute*
Inclination spread on axial rotation at 90º Inc
±0.10
<0.20
degrees
degrees
Azimuth accuracy, absolute 90º Inc
Azimuth spread axial rotation, 10º through 90º
±0.5
<1.0
degrees
degrees
Tool face accuracy, axial rotation at 90º Inc
±1.0
degrees
Total g field accuracy
±3.0
mG
Total H field accuracy, absolute
±3.0
nT

* Absolute accuracy is achieved when the instrument is tested in a controlled environment using a calibrated and certified reference position

 

 